RK500-06 ORP Sensor Water Quality Monitoring Sensor
PRODUCT DESCRIPTION
RK500-06 ORP sensor is simple and cost effective solution for a wide variety of waste water and process applications. This all-in-one sensor provides simultaneous measurement of ORP and temperature. The rugged Ryton body is designed for easy installation into on-line via the 3/4 inch tapered threaded connections provided on both ends of the sensor. The wide body sensors (26 mm diameter) hold four separate elements in one unbreakable Ryton body, large volume gelled electrolyte and the double junction reference system slows down depletion and poisoning extending the life time.
High precision.
High sensitivity.
Fast response.
Widely used.
Excellent stability.
Simple operation.
SPECIFICATIONS
Item |
Technical Specification |
|
ORP |
Temperature(only for RS485) |
|
Measurement Principle |
Electrochemical(platinum ring) |
Thermal resistance |
Range |
-1500mV-+1500mV |
0-80℃ |
Resolution |
0.1mV |
0.1℃ |
Accuracy |
±0.5mV |
±0.5℃ |
Supply |
7-30VDC |
|
Response time |
5s |
|
Output |
4-20mA & RS485 at the same time |
|
Operating Environment |
-10-+80℃(<0.6MPa) |
|
Stability |
≤1%/year |
|
Maintenance |
Every 1 months to clean the electrode, every 6 months calibrated |
|
Power consumption |
<0.4W |
|
Ingress Protection |
IP68 |
|
Storage |
10-60℃@20%-90%RH |
|
Cable length |
5m default, customizable |
DIMENSION
Universal type ABS housing, Up and down are NPT3/4 threads
Standard glass type Length=120mm
Highly corrosion resistant PPS housing, Up and down are NPT3/4 threads
ELECTRODE MAINTENANCE & INSTALLATION AND FIXED
PH electrode is not used at ordinary times and can be soaked in 3mol/l KCL solution or saturated KCL solution. It is strictly prohibited to immerse the electrode in distilled water and deionize the water or tap water with minimal plasma content.If the PH electrode is contaminated with inorganic substances, it can be cleaned with 0.1mol/l Hcl or NaOH solution for a few minutes and then washed with distilled water. If the PH electrode is contaminated with organic substances, it can be cleaned with alcohol or acetone and then cleaned with distilled water.(note: the protective cap before the electrode should be removed when using);
Clean the electrode with tap water every 3 months or 6 months according to the working environment.
Mounting bracket(length=1m) is optional
PRODUCT DETAILS
Product Principle & Material
Product Features
PRODUCT APPLICATION
Agricultural Irrigation
Urban Sewage
River
Reservoir
Biodegradation
Chemical
Water Treatment
Well