AB7677 - Anybus X-gateway – EtherNet/IP Scanner - CANopen Slave

Giá bán: Liên hệ

Mã sản phẩm: AB7677

Thương hiệu: Anybus - HMS Industrial Networks

Tình trạng: Còn hàng

Ordering Information

ORDER CODE: AB7677

INCLUDED COMPONENTS:
- Quick start documentation
- USB configuration cable
- Configuration software available for download
- Anybus OPC server software available for download
- (Power supply not included)

Tư vấnhotline0965746247

Anybus X-gateway – EtherNet/IP Scanner - CANopen Slave

The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between EtherNet/IP and CANopen networks.

FAST COPYING OF I/O DATA

The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Scanner on the EtherNet/IP network and as a Slave on the CANopen network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

x-gateway-eipm-cops

    DatasheetFile download

    AB7677

    Features and benefits

    • Fast copying of cyclic I/O data between EtherNet/IP and CANopen networks (10-15 ms)
    • Proven and tested with all PLC manufacturers
    • Powerful Scanner interface eliminates the need for a PLC controller on the EtherNet/IP network
    • Supports up to a maximum of 512 bytes of Input and Output data in each direction
    • 10/100 Mbit/s Dual-port EtherNet/IP adapter interface with IT functionality
    • Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
    • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
    • Optional control status information added to I/O data for diagnostic purposes
    • Global free technical support and consultancy

    EtherNet/IP Scanner/Master interface

    An Anybus X-gateway with an integrated EtherNet/IP Scanner interface can be used when there is no existing EtherNet/IP controlling PLC. The X-gateway will perform EtherNet/IP Scanner functions.

      • EtherNet/IP CONFORMANCE TESTED™ by ODVA 
      • Connects up 64 EtherNet/IP Adapter/Slaves
      • 10/100Mbit operation in full or half-duplex
      • Max. 509 bytes Input and 505 bytes Output data
      • Optional Live List of the active status of the connected adapters
      • Integrated FTP server provides easy file management using standard FTP clients.
      • Web server with dynamic data capability and Server Side Include (SSI) capability
      • Email client with dynamic data capability and Event-triggered email handling
      • Support for CIP Objects
      • DNS Capability
      • TCP/IP settings via on-board DIP switches, DHCP/ARP/Anybus IPconfig (HICP)
      • EtherNet/IP Scanner/Adapter network configuration via in-built web interface or RSLogix/Studio5000 software 
      • 1x RJ-45 Ethernet port

      CANopen Slave interface

      CANopen Slave settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.

      • Complete CANopen slave functionality according to CANopen Version 4.02
      • Max 512 bytes of Input and 512 bytes of Output data (PDO + SDO)
      • Customizable PDO mapping
      • Up to 80 RPDO’s and 80 TPDO’s
      • Transmission types: PDO Sync, Change-of-state, Event based and RTR
      • Network store/restore functionality
      • Heartbeat & Node Guarding support
      • Supports CANopen baudrates 10 kbit/s – 1 Mbit/s
      • CANopen configuration via .EDS file or via on-board rotary switches
      • 1x D-sub 9-pin male CANopen connector

      Technical specifications

      Dimensions (L•W•H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
      Weight 400g or 0,880 lbs
      Operating temperature -25 to +65 °C  or  -13 to +149 °F 
      Storage temperature -40 to +85 °C  or  -40 to +185 °F 
      Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
      Current consumption     max. 400mA (Typical 200mA)
      Enclosure material  Aluminium and plastic
      Installation position Vertical / Flat*
      Galvanic isolation YES, on both BUS/Ethernet side
      Mechanical rating IP20, NEMA rating 1
      Mounting DIN-rail (EN 50022 standard)
      I/O configuration via USB port with Anybus Configuration Manager software
      Certifications CE, CULUSRoHS

      Ordering Information

      x-gateway-eipm-cops

      ORDER CODE: AB7677

      INCLUDED COMPONENTS:
      - Quick start documentation
      - USB configuration cable
      - Configuration software available for download
      - Anybus OPC server software available for download
      - (Power supply not included)
       

      GUARANTEE:  3 years

      Để được tư vấn miễn phí

      Quý khách hàng vui lòng để lại thông tin bên dưới

      zalo