AS-Interface Master - Modbus RTU Slave - AB7828-F

Giá bán: Liên hệ

Mã sản phẩm: AB7828-F

Thương hiệu: HMS

Tình trạng: Còn hàng

Ordering Information

ORDER CODE: AB7828-F

INCLUDED COMPONENTS:
- Quick start documentation
- USB configuration cable
- Configuration software available for download
- Anybus OPC server software available for download
- (Power supply not included)

    Tư vấnhotline0965746247

    Anybus X-gateway - AS-Interface Master - Modbus RTU Slave

    The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between AS-Interface and Modbus RTU networks.

    FAST COPYING OF I/O DATA

    The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Master on AS-Interface network and a Slave on the Modbus RTU network. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.

    EASY CONFIGURATION - NO PROGRAMMING REQUIRED!

    The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.

      Features and benefits

      • Fast copying of cyclic I/O data between two networks (10-15 ms)
      • Proven and tested with all PLC manufacturers
      • Supports up to a maximum of 512 bytes of Input and Output data in each direction
      • Powerful Master interface for AS-Interface eliminates the need for a PLC controller
      • Optional control and status information added to the I/O data for diagnostic purposes
      • Robust stand-alone housing for use in harsh industrial environments
      • Global free technical support and consultancy

      AS-Interface Master Interface

      An Anybus X-gateway with an integrated AS-Interface M4 Master interface can be used when there is no existing AS-Interface controlling PLC.

      • Complies to AS-Interface 3.0 specification
      • Controls up to 62 AS-Interface slaves
      • Optional Live List of the active status of the connected slaves
      • Supports Combined Transaction Types 1, 2, 3, 4 and 51
      • Up to 248 digital inputs and 186 digital outputs
      • Up to 124 (16-bit) analog values
      • AS-Interface baudrate 167 kbit/s
      • Synchronous I/O (optional)
      • On-board configuration button
      • 1x D-sub 9-pin male connector (RS-232) for terminal-based monitoring and configuration
      • 2x 2-pin 5,08 Phoenix plug connectors

      Modbus RTU Slave interface 

      Modbus RTU network address settings made via on-board configuration switches 

      • Complete Modbus RTU slave functionality
      • Max 512 bytes of Input and 512 bytes of Output data
      • Modbus diagnostics support
      • Configuration via on-board DIP switches
      • Modbus RTU baudrate 12-57,6 kbit/s
      • 1x D-sub 9-pin female network connector

      Technical specifications

      Dimensions (L•W•H)   114 x 44 x 127mm or 4,49 x 1,73 x 5,00"
      Weight 400g or 0,880 lbs
      Operating temperature -25 to +65 °C  or  -13 to +149 °F 
      Storage temperature -40 to +85 °C  or  -40 to +185 °F 
      Power supply 24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector  
      Current consumption     max. 400mA (Typical 200mA)
      Enclosure material  Aluminium and plastic
      Installation position Vertical / Flat*
      Galvanic isolation YES, on both BUS/Ethernet side
      Mechanical rating IP20, NEMA rating 1
      Mounting DIN-rail (EN 50022 standard)
      I/O configuration via USB port with Anybus Configuration Manager software
      Certifications CE, CULUSRoHS

      Để được tư vấn miễn phí

      Quý khách hàng vui lòng để lại thông tin bên dưới

      zalo