Anybus X-gateway – CC-Link IE Field Slave - Modbus TCP Server
The Anybus X-gateway allows you to seamlessly inter-connect PLC control systems and their connected devices between CC-Link IE Field and Modbus TCP networks.
FAST COPYING OF I/O DATA
The X-gateways primary function is with the fast transfer of cyclic I/O data between the two networks. This offloads your PLC from working with additional calculations. The gateway acts as a Slave/Server on both networks. The data transmission is completely transparent with a maximum data capacity of 512 bytes in each direction.
EASY CONFIGURATION - NO PROGRAMMING REQUIRED!
The connection between the two networks is quickly set up in the Anybus Configuration Manager software, included with the X-gateway. No programming skills are needed to set up the X-gateway. As factory default the X-gateways have a pre-defined I/O size of 20 bytes I/O.
Features and benefits
- Fast copying of cyclic I/O data between the two networks (10-15 ms)
- Proven and tested with all PLC manufacturers
- Supports up to a maximum of 512 bytes of Input and Output data in each direction
- Possibility to build web pages displaying and controlling a factory floor process with data from the other connected network
- Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server
- Optional control status information added to I/O data for diagnostic purposes
- Robust stand-alone housing for use in harsh industrial environments
- Global free technical support and consultancy
CC-Link IE Field interface
CC-Link IE Field Slave settings can be made either via on-board switches, or by importing the provided .CSP file into engineering tool of the controlling PLC.
- CC-Link IE Field interface of the X-gateway is conformance tested and approved by CLPA
- CC-Link Specification (Profile), publication BAP-05028-B
- Acts as a CC-Link IE Field Network Intelligent Device Station
- Max 512 bytes Input and 512 bytes I/O data
- On CC-Link IE Field: Max of 832 I/O points and 204 words Input and 832 I/O points and 204 words Output
- Baudrate 1 Gbit/s fixed operation
- TCP/IP settings configurable with web-page, Configuration Tool, DHCP or ARP
- CC-Link IE Field station setting via on-board switches
- 2x RJ-45 ports available simultaneously
Modbus TCP Slave interface
Modbus TCP Slave settings can be made either via the built-in web interface, or by importing the provided .EDS file into engineering tool of the controlling PLC.
- Conforms to Modbus TCP v1.0
- Modbus TCP class 0, class 1 and partially class 2 slave functionality
- 10/100Mbit operation in full or half-duplex
- Integrated FTP server provides easy file management using standard FTP clients
- Web server with dynamic data capability and Server Side Include (SSI) capability
- Email client with dynamic data capability and Event-triggered email handling
- Per-user security framework
- Quality of Service (QoS) available
- DNS Capability
- TCP/IP settings via DHCP/ARP/Anybus IPconfig (HICP)
- Integrated switch allowing for a daisy-chain topology
- 2x RJ-45 ports available simultaneously.
Technical specifications
Dimensions (L•W•H) |
114 x 44 x 127mm or 4,49 x 1,73 x 5,00" |
Weight |
400g or 0,880 lbs |
Operating temperature |
-25 to +65 °C or -13 to +149 °F |
Storage temperature |
-40 to +85 °C or -40 to +185 °F |
Power supply |
24 VDC +/- 20% via 2-pole 5.08 mm Phoenix pluggable screw connector |
Current consumption |
max. 400mA (Typical 200mA) |
Enclosure material |
Aluminium and plastic |
Installation position |
Vertical / Flat* |
Galvanic isolation |
YES, on both BUS/Ethernet side |
Mechanical rating |
IP20, NEMA rating 1 |
Mounting |
DIN-rail (EN 50022 standard) |
I/O configuration |
via USB port with Anybus Configuration Manager software |
Certifications |
CE, CULUS, RoHS |