Daikin AC Domestic units to BACnet IP/MSTP Interface

The Daikin-BACnet gateway allows fully bi-directional communication between Daikin Domestic Air Conditioner units and BACnet IP or MSTP networks.

FEATURES

  • BTL mark ensures full interoperability with BACnet devices.
  • Support BACnet IP and BACnet MS/TP.
  • Configuration from onboard DIP-switches.
  • IP settings available in a web interface.
  • Quick and easy installation (plug and set the DP-SW).
  • External power not required.
  • Simultaneous control of the AC unit by the IR remote controller and by BACnet IP or MS/TP.
  • Reduced dimensions 93 x 53 x 58 mm.
  • Mountable on DIN rail, wall, or even inside the indoor unit in some models of AC.
  • Abstraction of Air Conditioning unit properties and functionalities as fixed BACnet Objects.
  • Occupancy function allows energy savings. Costs related to HVAC systems in a building are one of the highest and this type of functions allow to reduce them.
  • Total control and monitoring of the AC unit from BACnet, including AC unit’s internal variables, running hours counter (for filter maintenance control) and error indication.

Use Case

Integration of Daikin Domestic Air Conditioner Units into a BACnet installation.

DK-AC-BAC-1

Description

DIRECT CONNECTION TO INDOOR UNITS

The gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the monitoring of errors, alarms and some internal variables.

FAST AND EASY TO SET UP BY DIP-SW    

The product can be installed and set up in a really short time. It’s only a matter of wiring the gateway to the AC unit and configure the DIP-SW accordingly. No configuration software and no power supply are required.

The product offers a web interface to easily monitor and control the indoor unit connected to the gateway. Additionally, the IP network settings can be stablished from this web interface.

Technical Documentation

User Manual General information about this product Download
Installation Manual Learn how to install the device in your project Download
EDE Download EDE file Download
HVAC Compatibility tool Find the appropriate solution for your HVAC integration Open
HVAC Compatibility Check your HVAC compatibility Download
BTL Certification Check the product certification Download
EC Declaration of Conformity Check the product certification Download

Commercial Documentation

Marketing Datasheet Discover all the integration solutions for Daikin Download
Intesis Brochure Know more about the Intesis current available products Download

HVAC Compatibility

Ensure the compatibility of this gateway with your AC model by visiting https://compatibility.intesis.com/

Compatible AC models

FTXR - E*** | FTXZ - N*** | CTXU - G*** | FTXG - C/E/J/L*** | FTXJ - L/M/MS/MW*** | CTXG50E/J*** | ATX50E*** | ATX - JV*** | ATX - KV*** | ATX - J/J2/J3/K*** | ATXL - JV/J2V*** | ATXM - M*** | ATXP - KV*** | ATXS - C/D/E/G*** | ATXS - K*** | ATXS - K*** | ATXS - KV*** | ATKS - C/D/E*** | ATXG - C/E*** | CTXA15A*** | CTXA - AW/AS/AT | CTXM15M*** | CTXS - K*** | CTXS - LVJU | CTXS - L*** | FT - FVM | FTDK - FV/GV*** | FTK - GV/JV*** | FTK - GV*** | FTK - NMVJU | FTK - N*** | FTKD - B*** | FTKD - BVMA | FTKD - BVMS | FTKD - BVMT | FTKD - D*** | FTKD - GV*** | FTKE - BVM | FTKE - BVMA | FTKN - NMVJU | FTKN - N*** | FTKS - B/C/D/E/F/G/H/J/K/L*** | FTN - E/F*** | FTS - B*** | FTYS - BVMS | FTX - GV/JV/J2/J3/K*** | FTX - GV*** | FTX - K*** | FTX - KV*** | FTX - LVMA | FTX - NMVJU | FTX - N*** | FTXA - A*** | FTXA - AW/AS/AT | FTXB - C*** | FTXC - B | FTXD - B*** | FTXD - B*** | FTXD - D*** | FTXD - JV*** | FTXG - L*** | FTXJ - PVMA*** | FTXL - G*** | FTXL - JV/J2V*** | FTXLS - K/K3*** | FTXM - K*** | FTXM - K*** | FTXM - M*** | FTXM - RVMZ | FTXN - NMVJU | FTXP - KV*** | FTXS  - B/C/D/E/F/H/J*** | FTXS - G*** | FTXS - K*** | FTXS - K*** | FTXS - LVJU | FTXS - L*** | FTYN - E/F*** | FVKS - B*** | FVXG - K*** | FVXM - F*** | FVXS - B/F*** | FVXS - NVJU | FVXS - N*** | FLX - A*** | FLXS - B/GV*** | FLK - A*** | FLKS - B*** | FVXS - B*** | CDKD - C*** | CDXS - C*** | CDXS - EAVMA | CDXS - E*** | FDKS - CVMA | FDKS - C/E*** | FDXS - C/E/L*** | FDXS - L*** | CTXG - QVJIJW | CTXG - QVJU(W/S) | CTXS - JVJU | CTXS - GVJU | CTXS - HVJU | CTXS - LVJU | CTXS - K | FTKN - JEVJU | FTXN - JEVJU | FTXN - KEVJU | FTXN - KVJU | FTXS - DVJU | FTXS - HVJU | FTXS - HVJU | FTXS - LVJU | FTXS - LVJU | FVXS - NVJU | CDXS - LVJU | FDXS - DVJU | FDXS - LVJU | CDXS - BVM | FT - JV1A | FT - GAVEA | FTKD - BVM | FTY - GAV1A | FTXE - BVMA | FTXE - BVM | FLX50AVMA | FLX60AVMA | FTKD - F*** | FTKE - G*** | FTKS - D*** | FTKS - E*** | FTKS50B*** | FTKS - G*** | FTKS - F*** | FTKS71H*** | FTN - J*** | FTXS - E*** | FTXS - F*** | CDKD - EAVM | CDKD - CVM | FDKS - EAVMB | FDKS - CAVMB | FTXM - QVMA | FTXM - QVMA | FTKM - QVMA | FTKM - QVMA | FTKM33NV2S | FTKM - SV2S | FTKM18SV2S | FTXM - PVMA | FTKM - PVMK | FTKXM - PVMK | FTXZ - NV1B | FTXJ - PVMAW | FTXJ - PVMAS

* The asterisks stand for any character in the asterisk' position.

ORDER CODE:

INBACDAI001I000  Daikin AC Domestic units to BACnet IP/MSTP Interface - 1 unit

INCLUDED COMPONENTS:

  • Intesis Gateway.
  • Installation Manual.
  • AC Connection cable.

Để được tư vấn miễn phí

Quý khách hàng vui lòng để lại thông tin bên dưới

zalo